■ Outline
The MS2830A-044/045 Signal Analyzer includes a spectrum analyzer function for measuring up to 110 GHz using an external mixer based on the 26.5 GHz/43 GHz upper frequency limit. It supports measurements of Tx characteristics, including adjacent channel leakage power, spectrum mask, and frequency counter, as well as spurious measurements requiring a wide dynamic range.
Installing the 10/31.25/62.5/125 MHz analysis bandwidth option adds signal analyzer functions for checking phenomena that are hard to check using a spectrum analyzer, such as frequency vs. time, phase vs. time, spectrogram, and CCDF. In addition, optional measurement software supports modulation analysis. Moreover, installing a preselector bypass option enables use of the signal analyzer and modulation analysis functions up to 26.5 GHz/43 GHz (MS2830A-044/045). Finally, it can be customized to support a range of application-specific measurements.
■ Key Performance
Application | Model No. | Name/Functions | Brochure | Product Introduction |
Spectrum Analyzer | MS2830A-044 MS2830A-045 |
26.5 GHz Signal Analyzer 43 GHz Signal Analyzer |
Download | Download |
Signal Analyzer | MS2830A-005 MS2830A-006 MS2830A-009 MS2830A-077 MS2830A-078 |
Analysis Bandwidth Extension to 31.25 MHz (Requires opt.006) Analysis Bandwidth 10 MHz Bandwidth Extension to 31.25 MHz for Millimeter-wave (Requires opt.006, for MS2830A-045) Analysis Bandwidth Extension to 62.5 MHz (Requires opt.006,005/009) Analysis Bandwidth Extension to 125 MHz (Requires opt.006,005/009,077) |
||
3GPP LTE (FDD) | MX269020A | LTE Downlink Measurement Software | Download | Download |
MX269020A-001 | LTE-Advanced FDD Downlink Measurement Software | |||
MX269021A | LTE Uplink Measurement Software | Download | ||
3GPP LTE (TDD) | MX269022A | LTE TDD Downlink Measurement Software | Download | |
MX269022A-001 | LTE-Advanced TDD Downlink Measurement Software | |||
MX269023A | LTE TDD Uplink Measurement Software | Download | ||
WLAN | MX269028A | WLAN (802.11) Measurement Software | Download | |
MX269028A-001 | 802.11ac (80 MHz) Measurement Software | |||
WLAN/Bluetooth | MX283027A-001 | WLAN Test Software | Download | |
MX283027A-002 | Bluetooth Test Software | |||
W-CDMA/HSPA/HSPA Evolution Base station |
MX269011A | W-CDMA/HSPA Downlink Measurement Software | Download | |
W-CDMA/HSPA/HSPA Evolution Mobile terminal |
MX269012A | W-CDMA/HSPA Uplink Measurement Software | Download | |
W-CDMA | MX269030A | W-CDMA BS Measurement Software | ||
GSM/EDGE | MX269013A | GSM/EDGE Measurement Software | Download | |
MX269013A-001 | EDGE Evolution Measurement Software | |||
TD-SCDMA | MX269015A | TD-SCDMA Measurement Software | ||
TDMA type | MX269017A | Vector Modulation Analysis Software | Download | |
CDMA2000 Base station | MX269024A | CDMA2000 Forward Link Measurement Software | Download | |
MX269024A-001 | All Measure Function NEW | |||
1xEV-DO Base station | MX269026A | EV-DO Forward Link Measurement Software | ||
MX269026A-001 | All Measure Function NEW | |||
Noise Figure Measurement | MS2830A-017 | Noise Figure Measurement Function | Download | Download |
BER Measurement | MS2830A-026 | BER Measurement Function |
Features
Specifications
Basic Performance
Items |
Specifications |
|
Frequency
|
Frequency range
|
9 kHz to 26.5 GHz (MS2830A-044) 9 kHz to 43 GHz (MS2830A-045) |
SSB phase noise (500 MHz) |
+18OC to +28OC -115 dBc/Hz (100 kHz ofset) -133 dBc/Hz (1 MHz offset) |
|
General |
Dimensions and mass |
426 (W) x 177 (H) x 390 (D) (Exclusive of surface projection) ≤15Kg (Excluding other options) |
Spectrum Analyzer
Frequency |
Resolution bandwidth (RBW) |
Setting range: 1 Hz to 3MHz (1-3 sequence), 50 kHz, 5MHz, 10MHz , 20 MHz*, 31.25 MHz* * Can be set when with MS2830A-005, Cannot be set when the MS2830A-009 |
Resolution bandwidth (CISPR RBW) |
with MS2830A-016 Setting range: 200 Hz (6 dB), 9 kHz (6 dB), 120 kHz (6 dB), 1 MHz (Impulse) |
|
Amplitude
|
Displayed average noise level (DANL)
|
+18º to +28ºC Detector: Sample, VBW: 1 Hz (Video average), Input attenuator: 0 dB without MS2830A-067/068, Frequency band mode: Normal −134 dBm/Hz (100 kHz) −144 dBm/Hz (1 MHz) −153 dBm/Hz (30 MHz ≤ f < 1 GHz) −150 dBm/Hz (1 GHz ≤ f < 2.4 GHz) −147 dBm/Hz (2.4 GHz ≤ f ≤ 3.5 GHz) −144 dBm/Hz (3.5 GHz < f ≤ 4 GHz) −144 dBm/Hz (4 GHz < f ≤ 6 GHz) −147 dBm/Hz (6 GHz < f ≤ 13.5 GHz) −145 dBm/Hz (13.5 GHz < f ≤ 18.3 GHz) −141 dBm/Hz (18.3 GHz < f ≤ 26.5 GHz) −141 dBm/Hz (26.5 GHz < f ≤ 34 GHz) −135 dBm/Hz (34 GHz < f ≤ 40 GHz) −132 dBm/Hz (40 GHz < f ≤ 43 GHz) |
Total absolute amplitude accuracy
|
+18º to +28ºC ±0.5 dB (300 kHz ≤ f < 4 GHz, Frequency band mode: Normall) (300 kHz ≤ f < 3.5 GHz, Frequency band mode: Spurious) ±1.8 dB (4 GHz ≤ f ≤ 13.8 GHz, Frequency band mode: Normal) (3.5 GHz ≤ f ≤ 13.8 GHz, Frequency band mode: Spurious) ±3.0 dB (13.8 GHz < f ≤ 26.5 GHz) ±3.0 dB (26.5 GHz < f ≤ 40 GHz) ±3.5 dB (nominal, 40 GHz < f ≤ 43 GHz) |
|
Spurious responses
|
2-tone 3rd-order intermodulation distortion |
+18º to +28ºC, ≥300 kHz separation without MS2830A-068, or Preamp: Off, Mixer input level: −15 dBm (1wave) TOI = +12 dBm (30 MHz ≤ f < 300 MHz) TOI = +15 dBm (300 MHz ≤ f < 3.5 GHz) TOI = +14 dBm (3.5 GHz ≤ f ≤ 6 GHz, Frequency band mode: Normal) TOI = +13 dBm (6 GHz < f ≤ 13.5 GHz) TOI = +13 dBm (13.5 GHz < f ≤ 26.5 GHz) TOI = +13 dBm (nominal, 26.5 GHz < f ≤ 40 GHz) |
Vector Signal Analysis (VSA) Function
General |
Trace mode |
Spectrum, Power vs. Time, Frequency vs. Time, Phase vs. Time, CCDF, Spectrogram, No Trace |
Analysis bandwidth |
1 kHz to 10 MHz (1-2.5-5 sequence) (with MS2830A-006) 1 kHz to 25 MHz (1-2.5-5 sequence), 31.25 MHz (with MS2830A-005, or with MS2830A-009) 1 kHz to 25 MHz (1-2.5-5 sequence), 31.25 MHz, 50 MHz, 62.5 MHz [with MS2830A-077] 1 kHz to 25 MHz (1-2.5-5 sequence), 31.25 MHz, 50 MHz, 62.5 MHz, 100 MHz, 125 MHz [with MS2830A-078] Note: An image response is received when setting the bandwidth to more than 31.25 MHz. This can be used when not inputting a signal frequency outside the MS2830A analysis bandwidth (125 MHz max.). The MS2690A/91A/92A Signal Analyzer series is recommended for other measurement purposes. |
|
Sampling rate |
2 kHz to 20 MHz (1-2-5 sequence) (with MS2830A-006) 2 kHz to 50 MHz (1-2-5 sequence) (with MS2830A-005, or with MS2830A-009) 2 kHz to 100 MHz (1-2-5 sequence) [with MS2830A-077] 2 kHz to 200 MHz (1-2-5 sequence) [with MS2830A-078] |
|
Maximum capture time |
0.5 s to 2000 s (determined according to analysis bandwidth) |
|
Spectrum displayed function |
Resolution bandwidth (RBW)
|
Setting range: 1 Hz to 1 MHz (1-3 sequence) [without MS2830A-077/078, or ≤31.25 MHz bandwidth] Setting range: 1 Hz to 3 MHz (1-3 sequence) [with MS2830A-077, >31.25 MHz bandwidth] Setting range: 1 Hz to 10 MHz (1-3 sequence) [with MS2830A-078, >31.25 MHz bandwidth] |
Displayed average noise level (DANL) |
without MS2830A-067/068, Frequency band mode: Normal −131.5 dBm/Hz (100 kHz) −141.5 dBm/Hz (1 MHz) −150.5 dBm/Hz (30 MHz ≤ f < 1 GHz) −147.5 dBm/Hz (1 GHz ≤ f < 2.4 GHz) −144.5 dBm/Hz (2.4 GHz ≤ f ≤ 3.5 GHz) −141.5 dBm/Hz (3.5 GHz < f ≤ 4 GHz) −141.5 dBm/Hz (4 GHz < f ≤ 6 GHz) −148.5 dBm/Hz (6 GHz < f ≤ 13.5 GHz) −146.5 dBm/Hz (13.5 GHz < f ≤ 18.3 GHz) −143.5 dBm/Hz (18.3 GHz < f ≤ 26.5 GHz) −143.5 dBm/Hz (26.5 GHz < f ≤ 34 GHz) −141.5 dBm/Hz (34 GHz < f ≤ 40 GHz) −137.5 dBm/Hz (40 GHz < f ≤ 43 GHz) |
|
Total absolute amplitude accuracy |
+18º to +28ºC without MS2830A-068, or Preamp: Off ±0.5 dB (300 kHz ≤ f < 4 GHz, Frequency band mode: Normal) (300 kHz ≤ f < 3.5 GHz, Frequency band mode: Spurious) ±1.8 dB (4 GHz ≤ f ≤ 13.8 GHz, Frequency band mode: Normal) (3.5 GHz ≤ f ≤ 13.8 GHz, Frequency band mode: Spurious) ±3.0 dB (13.8 GHz < f ≤ 26.5 GHz) ±3.0 dB (26.5 GHz < f ≤ 40 GHz) ±3.5 dB (nominal, 40 GHz < f ≤ 43 GHz) |
|
Measure function |
Adjacent channel power (ACP), Channel power, Occupied bandwidth (OBW) |
|
Digitize function |
Captured waveform data saved to internal HDD or output to external devices |
Options
Data Sheet
Anritsu MS2830A Spectrum Analyzer/Signal Analyzer Data Sheet
011 805 5030 / 084 3797 031 - Phone orders
Monday-Friday, 08:00-17:00
Category: Spectrum Analyzer
Manufacturer: Anritsu
Product code - SKU: Anritsu MS2830A Microwave Spectrum Analyzer/Signal Analyzer